Professional Vector Frequency Inverter Single Phase 220V 1.5KW Svpwminput
Rated voltage / frequency
Single phase 220V 50Hz / 60Hz
Change the permissible value
Voltage: -20% ~ + 20% voltage unbalance rate: <3% Frequency: ± 25%
Output
Rated voltage
0
~
220V
Frequency Range
0Hz
~
500Hz
Frequency resolution
0.01Hz
Overload
150% of rated current for 1 minute, 180% rated current 3 seconds
The main control functions
Modulation
Optimization of space vector SVPWM modulation current
Control
No sense of vector control (with optimal low frequency compensation characteristics Dead)
Frequency accuracy
Digital setting: the highest frequency × ± 0 01%; simulation settings: the highest frequency × ± 0.2%
Frequency Resolution
Digital setting: 0.01Hz; simulation setting: the highest frequency × 0.1%
Starting frequency
0.40Hz
~
20.00Hz
Torque boost
Automatic torque boost, manual torque boost of 0.1% to 30.0%
V/FFFFF
curve
Five ways: constant torque V / F curve, one kind of user-defined multi-segment V / F curve mode and three kinds of reduced torque characteristic curve method (2.0 times the power, 1.7 times and 1.2 times the power of power)
Acceleration and deceleration curves
Two ways: linear acceleration and deceleration, S curve acceleration and deceleration; seven kinds of acceleration and deceleration time, time units (minutes / seconds)
Optional, up 6000 minutes
DC braking
DC braking start frequency: 0 ~ 15.00Hz
Braking time: 0 to 60.0 seconds braking current: 0 ~ 80%
Dynamic braking
Built-in dynamic braking unit, an external braking resistor
Jog
Jog Frequency Range: 0.1Hz ~ 50.00Hz, jog ramp time of 0.1 to 60.0 seconds
Built-in PI
Can easily form a closed loop control system
Multi-speed operation
Through the built-in PLC or control terminal to achieve multi-speed operation
Traverse
Can achieve preset frequency, center frequency adjustable wobble function
Automatic voltage regulation (AVR)
When the grid voltage changes, to maintain the output voltage constant
Automatic energy-saving operation
Depending on the load, automatically optimize V / F curve, energy-saving operation
Automatic flow limiter
During the current automatic limit on the run to prevent frequent overcurrent fault trip
Fixed length control
After stopping the inverter reaches the set length
Communication function
With RS485 standard communication interface, support MODBUS ASCII and RTU communication protocol in two formats. Has a master-slave multi-machine interaction function
Run function
Run the command channel
Operation panel given; given control terminal; serial port given; are three ways to switch
Frequency setting channel
Keyboard analog potentiometer given; keyboard
▲
,
▼
keys given; function code number given; serial port given; terminal UP / DOWN given; analog voltage reference; analog current setting; pulse given; combination to set; given way to a variety of switching at any time
Switch the input channel
Reverse instruction; 8 programmable digital inputs, can be set 35 kinds of functions.
Analog input channels
2 analog inputs, 4 ~ 20mA, 0 ~ 10V optional
Analog output channels
Analog output, 4 ~ 20mA or 0 ~ 10V optional, enabling output setting frequency, output frequency and other physical quantities
Switching pulse output channel
A programmable open collector output; 1 relay output signal; 0 ~ 20KHz pulse output signal one way to achieve a variety of physical output
Operation
Panel
LED digital display
Can display setting frequency, output voltage, output current and other parameters
External instrument display
Output frequency, output current, output voltage display other physical display
Key Lock
Achieve full lock keys
Parameter Copy
Remote control can be achieved using the keyboard function code parameter copy function between drives
Protection
Overcurrent protection; overvoltage protection; undervoltage protection; overheating protection; overload protection, etc
Optional parts
The brake assembly; remote operation panel; remote cable; keyboard mounts, etc.
Environment
Use spaces
Indoors, away from direct sunlight, dust, corrosive gases, oil mist, water vapor, etc.
Hyperion height
Lower than 1000 m (higher than 1000 m with derating)
Ambient temperature
-
10
℃~+
40
℃
Humidity
Less than 90% RH, non-condensing
Vibration
Less than 5.9 m / s 2 (0.6M)
Storage Temperature
-
20
℃~+
60
℃
Structure
Protection class
IP20 (in the selection of state or keyboard display unit status)
Cooling
Forced air
Installation
Wall, cabinet installation
Fri, 08 May 2020 10:36:15 GMT 637245597758924226 5C39737447DA64EA
SALES POLICY:
Your bid is a contract: place a bid only if you're serious about buying the item. If you are the winning bidder, you will enter into a legally biding contract to purchase the item. If payment is not received within 7 days, item may be offered to the next highest bidder or relisted at the seller's sole discretion.
RETURN POLICY :
We offer 90 days(used) or 180 days(new) free warranty (except consumables).we stand behind every product we sell.If you're not pleased with your purchase, we'll be happy to make an exchange or refund the product price less S&H within 7 days of your purchase. For any exchange or refund, we need the original receipt or a record of the purchase in our system, and the product must be in its original condition, including the box, packaging and all accessories. Shipping and handling charges are not refundable.
International Buyers:
We are NOT responsible for any custom duty or import tax. However, we will try our best to minimize it.
Wir sind NICHT für irgendeine Zollgebühr oder Importabgabe verantwortlich.
Nous ne sommes pas responsables de tout droit de douane ni taxe d'importation.
About US:
We are professional EBAY sales team and lots of ebay buyers very satisfied with our services. You can enjoy top-quality product and high-quality services from us.
payment :
Shipping :
Best
Customer Service
Prompt
Delivery
100% Money Back
Guarantee
Easy & Secure
Payments