-40%
GLOBUS - GENESY 3000 - Elektrostimulator 4 Kanälen - 423 prog
€ 533.28
- Description
- Size Guide
Description
SERVICE AND WARRANTYSATISFIED OR REIMBURSED
SECURE PAYMENTS
DESCRIPTION
Genesy 3000 is the jewel of the new Globus professional range, encompassing the very best that Globus has developed in technology and functions over recent years.
This second-generation professional electrostimulator was developed after the successful completion of a new hardware and software project to implement its potential uses in the medical, rehabilitation and physiotherapy fields.
The unit is larger than the previous models and has an ergonomic design. It runs on mains supply or battery, therefore it can be used both as a fixed station and as a portable unit.
Genesy 3000 is the most fully equipped electrostimulator for treating pain, stimulating tissue healing and treating neuromuscular dysfunctions.
The system was designed to enable a more effective and faster functional recovery to sports for athletes who have suffered injuries, at the same time reducing the chances of new injuries.
The programs were studied expressly both to solve the post-traumatic acute stage and to recover athletes who have had reconstructive surgery.
This machine also incorporates specific programs for preparing athletes for the most common sports disciplines.
A complete range of mainly aesthetic treatments for the body makes the unit an all-round package.
8 DIFFERENT TYPES OF CURRENT
The Genesy 3000 stands out in particular for providing all major medical-type currents:
EMS (Electro Muscle Stimulation)
TENS (Trans Cutaneus Nerve Stimulation)
MENS (Micro Current Stimulation)
Kotz with sinusoidal wave
Interferential currents
Triangular and trapezoidal wave currents for denervated muscles
Direct current for Ionophoresis
TECHNICAL FEATURES
Channels: 4 independent CHANNELS (8 electrodes)
Frequency: 0.3 – 150 Hz
Power: 120 mA per channel
Pulse amplitude: 40 – 450 µs
Waveform: Square, biphasic, symmetrical, compensated wave
Power supply: Power supply unit 18V – 3.3A
Battery: 12 V, 2000 mAh
Device in II A class
In compliance with the directive 93/42/CEE
SUPPLIED WITH
1 Carrying case
1 electrostimulator
4 Electrode connection cables
2 Iono electrodes + 2 elastic bands
1 Battery charger
4 Reusable adhesive electrodes (5x5 cm)
4 Reusable adhesive electrodes (5x9 cm)
1 Operating manual
Rehabilitation programs:
Rehabilitation programs use EMS currents to re-establish the normal conditions of muscular effectiveness in post-injury treatments.
Muscular simulation is a useful instrument when the normal neuromuscular functionality is damaged, too.
Program list:
Swollen Ankles - Quadriceps Atrophy - Hemiplegy-Upper Limbs - Hemiplegy-Lower Limbs - Recovery after ACL surgery - Functional recovery Lower Limbs - Multiple Sclerosis-Ankle Re-education
- Multiple Sclerosis-Leg Re-education - Multiple Sclerosis-Muscle Spasms - Shoulder Sublaxation Prevention - Vastus medialis reinforcement for Patella-femoral syndrome
Tens programs:
The Transcutaneous Electrical Nerve Stimulation (TENS) is an antalgic stimulation carried out with pulses reaching the peripheral nervous system by means of electrodes placed on the area to be treated.
The TENS stimulation takes place through symmetrical biphasic pulses with frequencies ranging from 8 to 200 Hz.
Program list:
High Frequency Antalgic Tens
- Hand Osteoarthritis - Endorphinic Tens - Post-surgical Pain - Chronic Pain - Shoulder Pain - Carpal Tunnel - Trapezius Pain - Knee Osteoarthritis - Rotator Cuff Tendinitis - Low Frequency Antalgic Tens - Muscle Pain
- Nerve compression - Spinal Compression - Spinal Osteoarthritis - Spinal Osteoporosis - Hip Osteoarthritis - Ankle Osteoarthritis - Muscle Tendon Injury - Post-surgical Pain (bones fractures and soft tissue injuries) - Sciatica
- Chronic Lumbago - Cervical Pain - Acute Pain Post Inguinal Hernia - Bursitis-Tendinitis - Muscle Injuries - Bone Fractures - Whiplash - Epicondylitis - Osteoarthritis
Microcurrent programs:
MENS currents use currents with intensity ranging from 10 and 500 µA (microampere, i.e. one millionth of an ampere).
Usually the MENS therapy includes two different phases. The first aims at reducing the pain felt by the patient, and the second aims at promoting the protein synthesis and ATP, thus accelerating the healing of tissues.
Program list:
Epicondylitis - S. H. Periarthritis - Muscle Restoration - Contusion - Edema - Skin Ulcera - Sciatica - Lumbago - Brachial Neuralgia - Acute Pain - Articular Pain
- Stiff Neck - Whiplash - Cervical Spondylosis - Shoulder Sprain - Carpal Tunnel - Knee Sprain - Knee Osteoarthritis - Ankle Sprain - Achille Tendon Inflammation - Patella Tendon Inflammation - Rotator Cuff Inflammation - Tendon inflammation
Interferential programs:
This type of current is called interferential because it creates an area of interference within tissues in the point where the fields intersect.
The interferential current is an alternate mid-frequency (2500 Hz - 4000 Hz - 10000 Hz) sinusoidal current that is modulated in width and characterized by a high capability to penetrate tissues. In addition, it canbetolerated very well even by particularly sensitive patients.
Program list:
Knee Osteoarthritis - Acute Lumbago - Cervical Pain - Chronic Lumbago - Frozen Shoulder - Knee post-surgical pain - Pain vertebral fracture - Knee post-surgical edema - Fibromyalgia
Incontinence:
Mixed Incontinence - Stress Incontinence - URGE Incontinence
Ionophoresis programs:
The ionophoresis program works by conveying pharmacological substances into the tissues by means of a unidirectional direct electric current.
The ions in the medical substance are transported into the organism through skin, which has low resistance to the current, reaching cell membranes.
Programs for denervated muscles:
The simulation of a denervated muscle is different from the stimulation of a healthy muscle because the activation of muscle fibers requires specific currents.
In the presence of a traumatic lesion of peripheral nerves, measuring chronaxies permits to determine whether the denervation is limited, partial or total.
Program list:
Rectangular pulse waveform 1 – 2 – 3
Triangular pulse waveform 1 – 2 – 3
Trapezoidal pulse waveform 1 – 2 – 3
Menu Electrotherapy:
Program list electrotherapy includes 192 parameter combinations EMS and 44 Russian (KOTZ)
Sport:
Capillarization - Warm-up - Pre-competition Warm-up - Active Recovery - Maximum Strength - Endurance Strength - Explosive Strength - Aerobic Endurance - Reactivity - Post-Competition Recovery - Decontracting - Hypertrophy
Fitness:
Firming - Bio-Pulse Firming - Sculpting - Bio-Pulse Sculpting - Toning - Mass Building - Body Sculpting - Definition - Jogging - Anaerobic Fitness - Aerobic Fitness - Cramp Prevention
Beauty:
Drainage - Lipolysis - Toning Massage - Skin Tone Improvement - Connective Massage - Post-Pregnancy Drainage - Post-Pregnancy Lipolysis - Post-Pregnancy Firming
SHIPMENT
Delivery
Upon delivery of the goods the customer is required to check:
That the number of packages delivered corresponds to what is stated in the transport document.
The packaging and adhesive tapes are intact.
ATTENTION !!! In case of tampering and / or damage the customer shall immediately report the shipment and / or delivery putting the writing on the delivery document received by courier. The customer then must report any damage within 2 (two) days of receipt of goods in the manner prescribed by the operator chosen for the shipment and / or delivery and / or operator.
Rates
Shipping rates are calculated based on the weight and volume of packaging. it is possible combine multiple items into one shipment to save on the final price of the shipment. The calculation of the expedition you will see listed directly in the final order.
PAYMENTS
ANDROS please the customers to indicate in the order form a telephone number or an e-mail valid. Here the method of payment currently available:
Paypal
Bank transfer
Credit card
BANK TRANSFER
The shipment of the order is carried out only when the actual crediting on the current account of ANDROS, which must occur within 5 working days from the date of the order, after which the order is deemed automatically canceled. ANDROS not responsible for any delays caused by the postal services or crediting bank.
PAYPAL
Payment with PayPal is immediate, then we will ship after 24-48 hours of being credited. ANDROS not responsible for any delays caused by the accreditation service PayPal.
RETURN
All our customers have the right of Return. The defective items or different from the description will be replaced or refunded at the expense of ANDROS.
The right of Return is subject to the following conditions:
1 - It is not possible apply teh Return on only part of the product (ex .: accessories, enclosed software, etc. ...);
2 - You can not apply the Return to audiovisual products or sealed software (including those included in the kit), once opened;
3 - The item purchased must be returned intact and in original packaging, complete in all its parts (including packaging and any documentation and accessories: manuals, cables, etc ...); To limit damage to the original package, we recommend to enter into a second box; It should be avoided in all cases the attachment of labels or tape directly on the packaging of the product;
4 - The item purchased must be returned in normal condition, as received; will not be accepted products used that indicate signs of damage, degradation or dirt.
5 - The shipping costs for returning the item are paid by the customer.
6 - Arrived at our company, the product will be examined to assess any damages not caused by transport. If the package and / or the original packaging are damaged, ANDROS will deduct from the refund due to a percentage, not exceeding 20%, towards the cost of restoration.
7 - In case of forfeiture of the right Return, the goods remain at the stock ANDROS, available to the customer to be sent at his expense