Duble Display Temperature Controller Celsius & Fahrenheit 10A Thermostat Switch
€ 5.11
- Description
- Size Guide
Description
Duble Display Temperature Controller Celsius & Fahrenheit 10A Thermostat Switch100% brand new and high quality
Features:
This Temperature Controller is an excellent and convenient multifunction device for controlling temperature and display Celsius & Fahrenheit value.
The temperature controller has the characteristic of high accuracy, high sensitivity, high stability.
Control temperature by setting the temperature setting value and the difference value.
Can be installed directly or embedded in industrial control equipment panel, convenient and quick.
Suitable for cold storage, seafood storage, water heater, domestic freezer, water tanks, refrigerator, industrial chiller, steamer, industrial equipment and other temperature control applications.
Widely used in the hatching area, equipment case, air conditioning system, temperature control protection and other fields.
Specification:
Input voltage: AC110~220V, DC24V, DC12V
Measurement temperature range: -55℃~+120℃
Resolution: 0.1
Accuracy: ±1 °C
Relay output contact capacity: heating: 10A/AC240V, cooling: 10A/AC240V
Sensor h type: imported NTC sensor
Shell material: PC + ABS fireproof
Panel size: 75x34mm/2.95x1.34inch
Installation size: 85x70x28mm/3.35x2.76x1.10inch
Cable length: 1m
Color: Gray
Quantity: 1 Set
Note: 1.Please allow 0-1cm error due to manual measurement. pls make sure you do not mind before you bid.
2.Due to the difference between different monitors, the picture may not reflect the actual color of the item. Thank you!
Package includes:
1 Set Duble Digital Display Temperature Controller
-------------
Instruction:
Normal mode: The red digital tube on the left shows the real-time temperature, and the blue digital tube on the right shows the set temperature.
Setting mode: The red digital tube on the left displays the setting mode, and the blue digital tube on the right displays the setting contents.
Code Cable:
P0: Working mode(H/C: H for heating, C for Cooling), Default: H.
P1: Return difference value, Setting range:0.2~10 , Default 2.
P2: High temperature alarm, Setting Range:(-55~120℃)/(-67~248℉) , Default 80℃/176℉.
P3: Low temperature alarm, Setting Range:(-55~120℃)/(-67~248℉) , Default -55℃/-67℉.
P4:Compensation value, Setting Range:-10~10, Default 0.
P5: Delayed Start, Setting Range:0-60min, Default 0.
P6: Unit, Setting Range: C/F , Default C.
Three-step Quick Setup
1.Confirm mode
Press and hold SET for 5 seconds, display P0. Press SET again to display the mode. Press +- to switch mode, H is heating mode, C is cooling mode
2. Set the difference value
The return difference is also how much to fall back after the set temperature stops. The default is 2. If you need to modify, please enter P1 mode, press SET again to display the difference, press +- to set the difference back.
3. Set the temperature
After the mode and hysteresis are set, confirm the return. At this time, the screen displays the real-time temperature. Press the SET screen once and press +- to set the desired temperature.
Note:
P0; working mode
This setting is mainly set to the value when the thermostat is used for the first time. If it is used for heating, it should be set to H. If it is used for cooling, it should be set to C.
P1; hysteresis setting
The hysteresis is the difference required when the thermostat reaches the set temperature and stops working again. For example, if we set the heating mode to a temperature of 37-40 degrees, then the difference is 3
P2; high temperature alarm value
When the temperature reaches the set value, there will be an alarm action and stop working.
P3; low temperature alarm value
When the temperature is lower than the set value, there will be an alarm action and stop working.
P4; temperature correction
These functions are used for temperature calibration. If there is a deviation between the detected temperature and the actual temperature, some functional effects can be used. The positive value = measured value + corrected value. For example, we measure the temperature at 25.6 degrees and actually 25.8 degrees. P4 can be used. Set to 0.2 then the final temperature is 25.6+0.2=25.8
P5; delayed start
This function is generally used for compressor refrigeration. If you purchase some thermostats for the refrigerator freezer, this value must be set. According to the compressor back pressure, the general setting is 3-6 minutes.
P6; C/F conversion
If you want to change to F value, change the unit to F, the unit display light is on. If you want to change it to C value, change the unit to C, the unit display light is not bright. If you want to convert quickly, exit the display, long press You can quickly convert units by adding 3 seconds.
If you are experiencing difficulties, please contact us for help.