-40%
-9~99℃ AC110-230V Aquarium Temperature Controller 6 Channel Relay Output
€ 13.45
- Description
- Size Guide
Description
Keywords you may need:Sensors
Modules
Esp8266
Board
R3&ATMEGA2560
NodeMCU
Sheild
Screw sheild
Nano Sheild
Relay
Temperature Controller
Displays
OLED LED&RGB
LCR
Amplifier
Power supply
Step Up
Step down
Converter
Switch
GPS
Light
Wireless/Wifi
Dear customer:
Thank you for visit our store,we are proffessional "Business & Industrie" seller for 10 years,our main products included:Sensors,modules devolpment board, LED displays, other IC procuts an so on,any question about DIY robot,Arduino,or Raspberry Pi will be welcome to discuss with us,we will try our best to supply the most advanced product and price,(if we sale more,the cost of made one product will be reduce and we will change or price to make you save more.
Hope you enjoying yourself here!
We appreciate your business!
Shipping
Payment
Refund
Feedback
Shipping
We will arrange shipping for you
within 24 Hours
after payment cleared except the holidays.
We only ship to the confirmed address provided by PayPal. Before you pay, please make sure your address in PayPal matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand.
-We ship items to Worldwide. Thank you!
-we will ship out the order in
1-2 business days
after payment cleared .Since it is international shipping ,delivery time is about 15--28 business days to arrive to most countries.
Payment
We accept PayPal payment ONLY.
Refund
* We believe our items are so outstanding. We are convinced you will be happy with your Purchase.
* If you do not satisfy with our items. Please simply return to us within 30 Days in original condition. Just pay for the returned postage. Then we can issue full refund to you after the returned item arrived at our warehouse.
* Please include your eBay ID and item number with any email requests.
Feedback
* When you satisfied with our product and services please leave us positive feedback.
* If you have got the package, please confirm "
Delivery on time
" For us.
* If a problem occurs, contact us immediately with any email request.
* Just contact us using the " Ask the seller a question" link on eBay.
-9~99℃ AC110-230V Aquarium Temperature Controller 6 Channel Relay Output
Product selling points:
Wide voltage adaptation range 110-230v wide voltage available
Wide output range, 6-way relay output
Heating module refrigeration module dual function
More accurate temperature calibration function
Six modules are more convenient to use
Main parameters:
Product Name: Aquarium controller
Working voltage: ac110 ~ 230V, 50 / 60Hz
Temperature measurement range: - 9 ~ 99 ℃
Measurement accuracy: ± 1 ℃
Display accuracy: ± 1 ℃
Sensor wire length: 1m
Output mode: 6-way relay output
Output capacity: 250VAC / 10A
working principle:
Heating and cooling function
Start heating when the set temperature is greater than the real-time temperature; When the set temperature is less than the real-time temperature, start refrigeration.
Timing and reservation functions
The timing function starts the oxygen supply from the current time after the timing is turned on, and stops the oxygen supply after the work reaches the set time; The reservation function starts the oxygen supply from the reservation time after the reservation is opened, and stops the oxygen supply after the work reaches the set time.
Return difference
In the heating mode, if the temperature is set to 30 ℃, the return difference is set to 5 ℃. Start heating when the real-time temperature is less than the set temperature. Because of the set return difference, when the real-time temperature is less than 25 ℃, start heating, and stop heating when the real-time temperature is greater than 30 ℃.
In the refrigeration mode, if the temperature is set to 25 ℃, the return difference is set to 5 ℃. When the real-time temperature is greater than the set temperature, start refrigeration. Because of the set return difference, when the real-time temperature is greater than 30 ℃, start the refrigeration, and when the real-time temperature is less than 25 ℃, stop the refrigeration.
Operating instructions
Lighting: press briefly to start lighting; Press briefly again to stop the lighting.
Filtering: press briefly to start filtering; Press briefly again to stop filtering.
Sterilization: press briefly to start sterilization; Short press again to stop sterilization.
Heating and cooling: in standby mode, long press the setting key, short press the setting key again, and then adjust the setting temperature by up and down. After adjustment, short press the setting key to set the return difference, adjust the return difference by up and down, and then short press the setting key again to exit.
Timing and reservation function: in standby mode, long press the setting key, and then switch to the timing function through up and down adjustment. First, briefly press the setting key, and then adjust the required timing time through up and down regulation. After the adjustment is completed, briefly press the setting key to confirm, and then start the oxygen supply. To stop oxygen supply, briefly press the oxygen supply key again.
Clock: in standby mode, long press the setting key, and then switch to the clock function through up and down adjustment. Briefly press the setting key first, and then adjust and adjust the calibration clock. After completion, briefly press the setting key to confirm.
Lock: after the standby time exceeds 30 seconds, the panel will automatically lock and can be unlocked by pressing the setting key for two times.
Power supply: in standby mode, short press to turn off the display and backlight, and the work indicator will not turn off; Short press again to open.
Temperature calibration: in standby mode, long press the setting key to switch to real-time temperature through up and down regulation, then short press the setting key to enter temperature calibration, and then calibrate through up and down regulation. After completion, short press the setting key.
Restore factory settings: in standby mode, press and hold the power key for 10 seconds to restore factory settings.
Operation example
[example] heating function: when the real-time temperature is lower than 40 ℃, the heater starts to work. When it is heated to 50 ℃, the heater stops working. be careful! The return difference between 50 ℃ and 40 ℃ is 10!
In standby mode, press and hold the setting key for about 5 seconds to enter the setting temperature. Press and hold the setting key for a short time, and the setting temperature flashes. Press and hold the setting key for a short time to adjust the setting temperature to 50 ℃. Press and hold the setting key for a short time to switch to the return difference. Adjust the return difference to 10 through up and down. Press and hold the setting key for confirmation and exit. After 5 seconds, Automatically restore to standby mode.
Refrigeration settings are the same.
[example] timing function: provide oxygen regularly for 3 hours, and automatically stop oxygen supply after 3 hours.
In standby mode, press and hold the setting key for about 5 seconds to enter the setting temperature, switch to the timing function through up regulation and down regulation, press the setting key briefly to enter the timing function, adjust to the timing for 3 hours through up regulation and down regulation, and press the setting key briefly to confirm and exit. After 5 seconds, it will automatically return to standby mode.
If you need to supply oxygen all the time from the current time, simply press the panel oxygen supply button or set the timing duration to --: --.
[example] reservation function: make an appointment to start oxygen supply at 21:00 p.m. for 2 hours.
In standby mode, press and hold the setting key for about 5 seconds to enter the setting temperature, switch to the reservation function through up regulation and down regulation, and briefly press the setting key to enter the reservation function, adjust to 21:00 p.m. through up regulation and down regulation (hours and minutes are switched through the setting key) -- > after the reservation time is set, briefly press the setting key, switch to the reservation function through up regulation and down regulation, Adjust the reservation duration to 2 hours -------- > briefly press the setting key to confirm and exit. After 5 seconds, it will automatically return to the standby state.
If you need to start oxygen supply from 21:00 p.m., set the reservation duration in this process to --: --.
matters needing attention
If the real-time temperature displays EE and the buzzer alarms all the time, please check whether the sensor is inserted to the bottom.
Any wiring must be carried out in the power off state
Non professional personnel are not allowed to disassemble this product without permission to avoid unnecessary danger
The product does not have a battery. Customers need to bring their own cr1220 battery
detailed list:
Thermostat * 1
Sensor wire * 1
Am 22.09.21 hat der Verkäufer die folgenden Angaben hinzugefügt: