-40%

12/24/110-220V STC-3000 Digital Display Temperature Controller Thermostat NTC

$ 5

Availability: 36 in stock
  • Marke: Markenlos
  • Type: Thermostat Sensor
  • Condition: New
  • Voltage: DC 12V
  • Brand: Unbranded
  • Analog/Digital: Digital

    Description

    integratemote
    integratemote
    Recommended
    New product
    12/24/110-220V STC-3000 Digital Display Temperature Controller Thermostat NTC
    M
    ain Instruction:
    Switch the modes between cool and heat;
    Control temperature by setting the temperature setting value and the difference value;
    Temperature calibration;
    efrigerating control output delay protection;
    Alarm when temperature exceeds temperature limit or when sensor error.
    Specification and Size:
    Front panel size: 75(L)x34.5(w)(mm)
    Mounting size: 71(L)*29(W)(mm)
    Product size: 75(L)x34.5(W)x85(D)(mm)
    sensor length: Im (include the probe)
    Technical Parameters:
    Temperature measuring range: 50°C~99°C
    Resolution: 0.1°C
    Accuracy: +1°C(-50°C~70°C)
    sensor error delay: l minute
    Power supply: STC-3000 DC 12V/STC-3000 DC 24V/STC-3000 AC 110-220V, 50/60Hz
    Power consumption: <3w
    Sensor: NTC sensor (IPC)
    Relay contact capacity: Cool(10A/250VAC); Heat(10A/250VAC)
    Ambient temperature: 0°C~60°C
    Storage temperature: -30°C~75°C
    Relative humidity: 20-85%(No condensate)
    Panel instruction
    Indicator light status instruction
    Indicator light
    Function
    Note
    Cool indicator ligh
    On:Refrigeration starts;Off:Refrigeration stops;Flash:compressor delay
    Cool、Heat indicator
    light can not be “on
    status simultaneously
    Heat indicator ligh
    On: heating starts;Off:heating stops
    Set indicator ligh
    On:parameter setting status
    Key operation instructructiom
    1. View parameter method
    When the controller is working normally, press and release the “▲” button once, Display the temperature set value, press and immediately release the “▼” button once to display the temperature difference set value, 2 seconds Return to normal temperature display state
    2. Set the parameter method
    When the controller is working normally, press and hold the “S” button for more than 3 seconds to enter the modified parameter mode, “Set The indicator light is on, and the digital tube displays the code "F1" of the first menu item.
    Press “▲” or “▼” to scroll up or down the menu item and display the menu code, press “S”
    The key displays the parameter setting value of the current menu. Hold down the “S” key and press and hold “▲” or “ the key can be adjusted up or down and the parameter setting value of the current menu is displayed, while holding down "S" and "▲"
    The key or “▼” key can quickly up or down and display the parameter settings of the current menu.
    After the completion, press and release the power button to save the parameter modification and return to the normal temperature display state.
    If there is no key operation within 0 seconds, the parameter modification will not be saved and return to the normal display state.
    “Er” is displayed if an error occurs while saving the parameter, and returns to the normal display state after 3 seconds.
    3.Repair system data
    When the machine is powered on, first check whether the parameter setting is normal. If the check is wrong, it will display “ER”. Pressing any key at this time will restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.
    Operation instruction
    Under controller normal working status, press and hold “ ” key for 3s can turn off the controller; Under controller “off” status, press and hold “ ” key for 3s can turn on the controller.
    Under the controller normal working status, screen displays the current temperature value; also the controller can also switch the working mode between heating and cooling.
    Controller starts refrigerating with cool indicator light on when the measuring temperature ≥ temperature set value + difference value, and the refrigerating relay is connected; The “Cool” indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature ≤ temperature set value, the Cool indicator light on, and refrigerating relay disconnects.
    System starts heating when the measuring temperature value ≤ the temperature set value-difference value, and the “Heat” indicator light on, and the heat relay connects; When the measuring temperature ≥ temperature set value, the “Heat” indicator light is off, and the heat relay disconnects.
    Menu instruction
    Code
    Function
    Set range
    Default
    Note
    F1
    Temperature set value
    -50

    99

    10

    F2
    Difference set value
    1

    10

    3

    F3
    Compressor delay time
    1

    10 minutes
    3 minutes
    F4
    Temperature calibration value
    -10
    ℃~
    10

    0

    F5
    Fainthearted /Celsius switching
    Set range
    0/1
    Error description
    Alarm when sensor error:Controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the running status is closed off with the buzzer alarms, and the nixie tube displays “EE”,Press any key can cancel alarm sound,system back to display the normal temperature when the error and the fault is cleared.Alarm when the measuring temperature exceeds temperature measuring range:Controller activates the error alarm function when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer alarms, and the nixie tube displays “HH”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
    Safety Regulations:
    ★Danger:
    1. Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong connections or overloading the relay.
    2. Dangers: Prohibit connecting the wire terminals without electricity cut-off.
    ★Warning:
    Prohibit using the machine under the environment of over damp, high temp., strong electromagnetism interference or strong corrosion.
    ★Notice:
    1. The power supply should conform to the voltage value indicated in the instruction.
    2. To avoid the interference, the sensor down-lead and power wire should be kept a distance.
    Wiring diagram
    Package included:
    1x STC-3000 Temperature Controller
    About us
    Payment
    Shipping
    Feedback
    Return Policy
    Contact Us
    About us
    1.A large number of products for you to choose
    2.We have an independent customer service team to quickly answer your questions
    Payment
    1.We accept PayPal payment ONLY, and must be received within 5 days from the date of purchase.
    2. It is easy and safe for you to pay by credit cards, debit cards, bank transfers and PayPal account balances. 3.Buyers are responsible for import duties,custom fees and taxes, if any, please check your country.
    Shipping
    1.We only ship to the confirmed address provided by eBay. please make sure your ebay address is 100% matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand.
    2.Orders will be processed instantly and dispatched within 1-2 business days except hoilday, so we do NOT accept any email/message note after you place orders.
    3.All package need to wait 30 days,Please take care it.Less than 30 days,we can't take a refund.
    Feedback
    1.We greatly appreciate your POSITIVE feedback. Please do NOT leave negative feedback without asking for help.
    2.Please DON'T leave negative or neutral feedback if you haven't received item in 30 days, because we have mentioned the shipping time repeatedly.
    Return Policy
    1.We believe our items are so outstanding. We are convinced you will be happy with your Purchase.
    2. If you do not satisfy with our items. Please simply return to us within 30 Days in original condition. Just pay for the returned postage. Then we can issue full refund or resend the item to you after the returned item arrived at our warehouse.
    3. Please include your eBay ID and item number with any email requests.
    Contact Us
    1. If you have any questions, please feel free to email our service specialists.
    2.Just contact us using the " Ask the seller a question" link on eBay.
    3.Our aim is to provide Top Level Customer Service, normally so we will try our best to solve any problem.
    Am 25.10.2022 hat der Verkäufer die folgenden Angaben hinzugefügt: